雅田主營:杭州工業風扇,工業吊扇,浙江大型工業風扇,工業節能風扇
NEWS CENTER
工業風扇需要注意哪些安全事項?
現代工業風扇的出產與制作過程中自身就充滿了很多的安全隱患,而且設備的自身在運用與裝置的途中也會呈現這樣活著那樣的問題,下面杭州雅田機電有限公司給我們介紹一下:
一、首要風險源
風險發作的原因和過程易引發事端
1、工業風扇絕緣性能不符合要求,并未采取維護措施,造成漏電。這種情況有或許會導致觸電現象。
2、工業大風扇的防護網罩損壞或網孔過大,人員不慎手指進入網罩內觸摸旋轉的扇葉。這種情況有一般會導致機械損傷。
3、大型工業風扇未及時檢修,并未定時丈量絕緣電阻,造成絕緣損壞,人員觸摸帶電部位。這種情況有或許也會導致觸電現象。
4、在易燃易爆場所違規作業,發作火花或靜電。這種情況一般會引起爆炸或火災。
二、發作事端的應急處理
1、發現大型工業風扇呈現裝置松動、位移、外殼帶電等現象,應立即封閉電扇,并報修。
2、遇有人身觸電風險的情況,應立即封閉電源開關,搶救觸電者,并應維護事端現場。
3、如發作機械損傷,應立即進行包扎、止血等處理,防止感染;嚴重的應立即到醫院處置。
三、工業大吊扇經過多重安全措施,根絕電扇或葉片的意外墜落
1、工業大吊扇的電扇吊架與鋼結構屋面經過螺栓緊固后,額外用鋼絲繩纏繞在屋面H型鋼和吊架之間。
2、電機及減速機的機架引申出4條鋼絲繩銜接至屋面,既可以限制電扇在工作時的振動,又提供了兩層維護。
3、工業大吊扇的葉軸銜接部分與減速電機的銜接選用反向螺紋緊固及錐形鋁軸襯。
4、專利規劃的Y型銜接臂設置了兩層定位裝置,防止葉片下墜。
5、特別規劃的安全環經過螺栓與葉片根部做兩層銜接
What safety issues do industrial fans need to pay attention to?
The production and manufacture of modern industrial fans are full of many safety hazards, and the equipment itself will also present such problems as living on the way to use and equipment. The following Hangzhou Yada Electromechanical Co., Ltd. introduces us to:
Primary sources of risk
Causes and processes of risk outbreaks are prone to incidents
1, industrial fan insulation performance does not meet the requirements, did not take maintenance measures, resulting in leakage of electricity. This situation may lead to electrocution.
2, the industrial fan's protective net cover was damaged or the net hole was too large, and the personnel accidentally touched the rotating fan leaf into the net cover. This situation generally leads to mechanical damage.
3, large-scale industrial fans did not repair in time, did not measure the insulation resistance regularly, resulting in insulation damage, personnel touch the charged parts. This situation may also lead to electrocution.
4, in the flammable and explosive site illegal operations, Spark or static electricity. This situation usually causes an explosion or fire.
Emergency response to incidents
1, found that large industrial fan display device loose, displacement, charged shell and other phenomena, should be immediately closed fan, and repair.
2, in the event of personal electric shock risk, should immediately close the power switch, rescue the electrocuted person, and should maintain the incident scene.
3, if the onset of mechanical damage, should be immediately bandaged, hemostasis and other treatment to prevent infection; Serious cases should be dealt with immediately at the hospital.
Third, the industrial large ceiling fan after multiple safety measures, the accidental fall of the fan or blade
1, the industrial large ceiling fan's electric fan suspension frame and steel structure roof after bolt fastening, extra wire rope wound between the roof H steel and suspension.
2, the frame of the motor and reducer has drawn 4 steel wire ropes connected to the roof, which can limit the vibration of the fan during work and provide two layers of maintenance.
3, the junction of the leaf shaft of the industrial large ceiling fan and the deceleration motor is connected by the use of reverse thread fastening and conical aluminum shaft lining.
4, the patent plan Y-type connecting arm is equipped with two layers of positioning devices to prevent the blade from falling.
5, the specially planned safety ring through the bolt and blade roots for two layers of connection
手機:18958153686(田經理)
電話:0571-82301378
傳真:0571-83697978